Estudio de la sensibilidad espacial en microanálisis con sonda de electrones

Tesis (Doctor en Física)--Universidad Nacional de Córdoba, Facultad de Matemática, Astronomía,Física y Computación, 2017.

Bibliographic Details
Main Author: Petaccia Trobatto, Mauricio Germán
Other Authors: Castellano, Gustavo Eugenio
Format: bachelorThesis
Language:spa
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/11086/5810
_version_ 1801212596868612096
author Petaccia Trobatto, Mauricio Germán
author2 Castellano, Gustavo Eugenio
author_facet Castellano, Gustavo Eugenio
Petaccia Trobatto, Mauricio Germán
author_sort Petaccia Trobatto, Mauricio Germán
collection Repositorio Digital Universitario
description Tesis (Doctor en Física)--Universidad Nacional de Córdoba, Facultad de Matemática, Astronomía,Física y Computación, 2017.
format bachelorThesis
id rdu-unc.5810
institution Universidad Nacional de Cordoba
language spa
publishDate 2018
record_format dspace
spelling rdu-unc.58102022-10-13T11:18:03Z Estudio de la sensibilidad espacial en microanálisis con sonda de electrones Petaccia Trobatto, Mauricio Germán Castellano, Gustavo Eugenio Excitación atómica e ionización Atomic excitation and ionization Simulación Monte Carlo Fluorescencia aecundaria Resolución espacial EPMA Reducción de varianza Tesis (Doctor en Física)--Universidad Nacional de Córdoba, Facultad de Matemática, Astronomía,Física y Computación, 2017. En el microanálisis por sonda de electrones (EPMA) es muy importante calcular adecuadamente el factor de reforzamiento por fluorescencia de manera de no distorsionar los análisis cuantitativos. Dado que los detectores son incapaces de discriminar los rayos x característicos primarios de los secundarios, la simulación Monte Carlo del transporte de radiación se vuelve una herramienta determinante en el estudio de este reforzamiento. Además, debido a que el camino libre medio de los fotones es mayor que el de los electrones de energía similar, la fluorescencia secundaria puede incrementar el tamaño del volumen analizado degradando de esta manera la resolución espacial de esta técnica. Conocer bien el tamaño del volumen de interacción para las diferentes señales detectadas en EPMA es determinante para estimar el tamaño mínimo de la región que puede ser analizada. En una primera instancia de esta tesis se estudió el reforzamiento por fluorescencia característica y por el continuo en aleaciones de Fe-Ni de diversas composiciones a diferentes energías de interés en EPMA utilizando las herramientas de simulación provistas en el paquete de rutinas PENELOPE. Luego, también mediante simulación Monte Carlo, se procedió a estudiar el efecto de la fluorescencia secundaria en el tamaño del volumen de interacción en diferentes materiales en un gran rango de números atómicos y varias energías de incidencia. In electron probe microanalysis (EPMA) an adequate assessment of the fluorescence correction factor is of fundamental importance in order not to distort quantitative analyses. Due to detectors are not capable of distinguishing primary and secondary characteristic photons, Monte Carlo simulation of radiation transport becomes a determinant tool in the study of this enhancement. In addition, given that the mean free path for photons is larger than that of electrons of similar energies, secondary fluorescence can increase the size of the analyzed volume thus degrading the spatial resolution of this technique. The knowledge of the size of the interaction volume is fundamental to estimate the minimum region of sample that can be studied. In this thesis the secondary fluorescence enhancement by characteristic as well as for continuum photons in Fe-Ni alloy of diverse composition and different beam energies is treated first using the simulation tools provided by the PENELOPE routine package. After this, also by Monte Carlo simulation, the effect of secondary fluorescence in the size of the interaction volume in different materials for a wide range of atomic numbers and beam energies was studied. 2018-02-08T16:34:11Z 2018-02-08T16:34:11Z 2017-03 bachelorThesis http://hdl.handle.net/11086/5810 spa Atribución 2.5 Argentina https://creativecommons.org/licenses/by/2.5/ar/
spellingShingle Excitación atómica e ionización
Atomic excitation and ionization
Simulación Monte Carlo
Fluorescencia aecundaria
Resolución espacial
EPMA
Reducción de varianza
Petaccia Trobatto, Mauricio Germán
Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title_full Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title_fullStr Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title_full_unstemmed Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title_short Estudio de la sensibilidad espacial en microanálisis con sonda de electrones
title_sort estudio de la sensibilidad espacial en microanalisis con sonda de electrones
topic Excitación atómica e ionización
Atomic excitation and ionization
Simulación Monte Carlo
Fluorescencia aecundaria
Resolución espacial
EPMA
Reducción de varianza
url http://hdl.handle.net/11086/5810
work_keys_str_mv AT petacciatrobattomauriciogerman estudiodelasensibilidadespacialenmicroanalisisconsondadeelectrones