Compressive strength of Biodentine®: mechanical vs. manual mix

Fil: Molina, Gustavo F. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.

Bibliographic Details
Main Authors: Molina, Gustavo F., Ulfohn, Javier, Arce Brissón, Georgette, Boetto, Cecilia, Mazzola, Ignacio, Brain Lascano, Laura, Zaya, Luis M., Sainz Aja, Martin, Pascualini, Carlos J., Farah, Martín, Farah, Miguel, Cabral, Ricardo J.
Format: publishedVersion
Language:spa
Published: 2024
Subjects:
Online Access:http://hdl.handle.net/11086/551041
_version_ 1806012151930814464
author Molina, Gustavo F.
Ulfohn, Javier
Arce Brissón, Georgette
Boetto, Cecilia
Mazzola, Ignacio
Brain Lascano, Laura
Zaya, Luis M.
Sainz Aja, Martin
Pascualini, Carlos J.
Farah, Martín
Farah, Miguel
Cabral, Ricardo J.
author_facet Molina, Gustavo F.
Ulfohn, Javier
Arce Brissón, Georgette
Boetto, Cecilia
Mazzola, Ignacio
Brain Lascano, Laura
Zaya, Luis M.
Sainz Aja, Martin
Pascualini, Carlos J.
Farah, Martín
Farah, Miguel
Cabral, Ricardo J.
author_sort Molina, Gustavo F.
collection Repositorio Digital Universitario
description Fil: Molina, Gustavo F. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina.
format publishedVersion
id rdu-unc.551041
institution Universidad Nacional de Cordoba
language spa
publishDate 2024
record_format dspace
spelling rdu-unc.5510412024-07-25T18:48:48Z Compressive strength of Biodentine®: mechanical vs. manual mix Resistencia a la compresión de Biodentine®: mezcla manual vs. Mecánica Molina, Gustavo F. Ulfohn, Javier Arce Brissón, Georgette Boetto, Cecilia Mazzola, Ignacio Brain Lascano, Laura Zaya, Luis M. Sainz Aja, Martin Pascualini, Carlos J. Farah, Martín Farah, Miguel Cabral, Ricardo J. Cementos dentales Silicatos Comportamiento físico Dental Cements Physical Performance Silicates publishedVersion Fil: Molina, Gustavo F. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Ulfohn, Javier. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Arce Brissón, Georgette. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina. Fil: Boetto, Cecilia. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina. Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Brain Lascano, Laura. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Zaya, Luis M. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Sainz Aja, Martin. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Pascualini, Carlos J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Farah, Martín. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Farah, Miguel. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Cabral, Ricardo J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. La incorporación de innovaciones tecnológicas en determinados materiales dentales, especialmente aquellos que requieren de aparatología específica para su uso y/o cuya pre-dosificación implica el descarte de una porción de su contenido, está condicionada por la relación costo-beneficio del producto. Según las instrucciones del fabricante, las cápsulas del silicato tricálcico Biodentine® (Septodont) deben activarse mediante el uso de mezcladores mecánicos luego de adicionar las proporciones exactas del líquido ad-hoc, utilizando la totalidad de cada cápsula de polvo y su respectiva ampolla del líquido, con un excedente de material considerable, según su indicación. Si bien es posible realizar la mezcla del cemento en forma manual prescindiendo de un amalgamador, una modificación en las recomendaciones del fabricante podría alterar las propiedades del material.OBJETIVO: Determinar si existen diferencias en la resistencia compresiva de Biodentine® según el método de mezcla utilizado: con activación mecánica y con mezcla manual.MATERIALES Y METODOS: Se confeccionaron probetas cilíndricas de 6 mm de alto por 4 mm de diámetro (n=6) para los dos grupos de estudio A) Biodentine® / Mezcla manual y B) Biodentine® / Mezcla mecánica. Las muestras fueron sometidas a la aplicación de una fuerza continua en máquina universal de ensayos Digimess RS-8000-5 a una velocidad de carrera de 1 mm/min hasta su ruptura. Se compararon los valores obtenidos entre los grupos mediante test de Student, determinando diferencias significativas para valores de p>0,05.RESULTADOS: Los valores medios obtenidos y su desviación estándar fueron A) 52.6 (16.3) MPa y B) 65.7 (30.6) MPa respectivamente. La distribución de valores de resistencia a la compresión según el grupo de estudio fue levemente superior en el grupo B, aunque las diferencias no fueron significativas (p=3,77). CONCLUSIONES: La mezcla manual no disminuye significativamente la resistencia a la compresión de Biodentine® en comparación al cemento mezclado mecánicamente. Economic circumstances may create difficulties in access to certain dental materials, especially those that a part of their content has to be disposed after mixing. According to the manufacturers´ instructions, capsules of tri-calcium silicate Biodentine® (Septodont) ought to be activated using a mechanical mixer after addition of the liquid accordingly. The whole content of a capsule is then used before the setting of the material. Aim: To compare the effect of the mixing mode on the compressive strength of Biodentine®, mixed manually and using a mechanical mixer. OBJECTIVE: To compare the effect of the mixing mode on the compressive strength of Biodentine®, mixed manually and using a mechanical mixer. MATERIALS AND METHODS Two groups were defined, A) Biodentine® / Manual mix and B) Biodentine® / Mechanical mix, with n = 6 cylindric specimens each of 6 mm height and 4 mm diameter. Samples were tested using a universal testing machine Digimess RS-8000-5 at a crosshead speed of 1 mm/min until fracture. Obtained values were compared using the Student-t test with a significance of p>0,05. RESULTS: Mean values were A) 52.6 (16.3) MPa and B) 65.7 (30.6) MPa respectively, finding no significant differences between the two groups (p=3,77). CONCLUSION: Compressive strength is not affected in Biodentine® when mixed manually compared to mechanical mixing. https://methodo.ucc.edu.ar/index.php/methodo/about publishedVersion Fil: Molina, Gustavo F. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Ulfohn, Javier. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Arce Brissón, Georgette. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina. Fil: Boetto, Cecilia. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Endodoncia; Argentina. Fil: Mazzola, Ignacio. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Brain Lascano, Laura. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Zaya, Luis M. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Sainz Aja, Martin. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Pascualini, Carlos J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Farah, Martín. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Farah, Miguel. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Fil: Cabral, Ricardo J. Universidad Nacional de Córdoba. Facultad de Odontología. Cátedra de Materiales Dentales; Argentina. Otras Biotecnologías de la Salud 2024-03-13T15:10:09Z 2024-03-13T15:10:09Z 2021 article 2545-8302 http://hdl.handle.net/11086/551041 spa Attribution-NonCommercial-ShareAlike 4.0 International http://creativecommons.org/licenses/by-nc-sa/4.0/ Digital
spellingShingle Cementos dentales
Silicatos
Comportamiento físico
Dental Cements
Physical Performance
Silicates
Molina, Gustavo F.
Ulfohn, Javier
Arce Brissón, Georgette
Boetto, Cecilia
Mazzola, Ignacio
Brain Lascano, Laura
Zaya, Luis M.
Sainz Aja, Martin
Pascualini, Carlos J.
Farah, Martín
Farah, Miguel
Cabral, Ricardo J.
Compressive strength of Biodentine®: mechanical vs. manual mix
title Compressive strength of Biodentine®: mechanical vs. manual mix
title_full Compressive strength of Biodentine®: mechanical vs. manual mix
title_fullStr Compressive strength of Biodentine®: mechanical vs. manual mix
title_full_unstemmed Compressive strength of Biodentine®: mechanical vs. manual mix
title_short Compressive strength of Biodentine®: mechanical vs. manual mix
title_sort compressive strength of biodentine r mechanical vs manual mix
topic Cementos dentales
Silicatos
Comportamiento físico
Dental Cements
Physical Performance
Silicates
url http://hdl.handle.net/11086/551041
work_keys_str_mv AT molinagustavof compressivestrengthofbiodentinemechanicalvsmanualmix
AT ulfohnjavier compressivestrengthofbiodentinemechanicalvsmanualmix
AT arcebrissongeorgette compressivestrengthofbiodentinemechanicalvsmanualmix
AT boettocecilia compressivestrengthofbiodentinemechanicalvsmanualmix
AT mazzolaignacio compressivestrengthofbiodentinemechanicalvsmanualmix
AT brainlascanolaura compressivestrengthofbiodentinemechanicalvsmanualmix
AT zayaluism compressivestrengthofbiodentinemechanicalvsmanualmix
AT sainzajamartin compressivestrengthofbiodentinemechanicalvsmanualmix
AT pascualinicarlosj compressivestrengthofbiodentinemechanicalvsmanualmix
AT farahmartin compressivestrengthofbiodentinemechanicalvsmanualmix
AT farahmiguel compressivestrengthofbiodentinemechanicalvsmanualmix
AT cabralricardoj compressivestrengthofbiodentinemechanicalvsmanualmix
AT molinagustavof resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT ulfohnjavier resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT arcebrissongeorgette resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT boettocecilia resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT mazzolaignacio resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT brainlascanolaura resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT zayaluism resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT sainzajamartin resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT pascualinicarlosj resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT farahmartin resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT farahmiguel resistenciaalacompresiondebiodentinemezclamanualvsmecanica
AT cabralricardoj resistenciaalacompresiondebiodentinemezclamanualvsmecanica