Electrificación de las nubes de tormenta : el mecanismo no inductivo

Tesis (Doctor en Física)--Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación, 2019.

Bibliographic Details
Main Author: Luque, Melina Yasmín
Other Authors: Bürgesser, Rodrigo Exequiel
Format: bachelorThesis
Language:spa
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/11086/12721
_version_ 1801213160890302464
author Luque, Melina Yasmín
author2 Bürgesser, Rodrigo Exequiel
author_facet Bürgesser, Rodrigo Exequiel
Luque, Melina Yasmín
author_sort Luque, Melina Yasmín
collection Repositorio Digital Universitario
description Tesis (Doctor en Física)--Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación, 2019.
format bachelorThesis
id rdu-unc.12721
institution Universidad Nacional de Cordoba
language spa
publishDate 2019
record_format dspace
spelling rdu-unc.127212022-10-13T11:19:58Z Electrificación de las nubes de tormenta : el mecanismo no inductivo Luque, Melina Yasmín Bürgesser, Rodrigo Exequiel Electricidad atmosférica Tormentas Atmospheric electricity Storms Electrificación Nubes de tormenta Mecanismo no-inductivo Tesis (Doctor en Física)--Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación, 2019. Fil: Luque, Melina Yasmín. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina. Numerosos estudios han identificado a la colisión entre partículas de hielo como el principal mecanismo de separación de carga en las nubes de tormenta. Este mecanismo se conoce como mecanismo de electrificación no-inductivo. Distintos experimentos de laboratorio han demostrado que la magnitud y el signo de la carga separada dependen de las condiciones microfísicas de las nubes tales como la temperatura ambiente, el contenido de agua líquida, la velocidad de colisión y el espectro de tamaños de las gotas de agua sobreenfriadas y de los cristales de hielo. En base a estos estudios se asume que, en ausencia de agua líquida o bajo condiciones de crecimiento húmedo de una de las partículas de hielo, el mecanismo no-inductivo no es capaz de funcionar. La presente tesis ha tenido como objetivo principal el estudio del mecanismo no-inductivo bajo tales condiciones. Para ello, se realizaron mediciones experimentales de la intensidad de la corriente de cargado eléctrico que adquiere un granizo simulado durante la colisión con cristales de hielo, creciendo por deposición de vapor, en ausencia de gotas de agua sobreenfriadas y, en una segunda parte, en condiciones de crecimiento húmedo del granizo. Los resultados obtenidos muestran que la carga transferida, bajo las condiciones estudiadas, es relevante y que el mecanismo de electrificación no-inductivo es capaz de funcionar de manera eficiente. Finalmente, estos resultados pueden ser incluidos en los modelos numéricos de electrificación de las nubes de tormenta para lograr una mejor representación de las mismas. Numerous studies have identified the collision between ice particles as the main mechanism of charge separation in thunderstorms. This mechanism is known as non-inductive electrification mechanism. Laboratory experiments have shown that the magnitude and sign of the separated charge depend on the microphysical conditions of thunderstorms such as ambient temperature, liquid water content, collision velocity and size spectra of supercooled water droplets and ice-crystals. Based on these studies it has been concluded that, in absence of liquid water or under wet growth conditions of one of the ice-particles, the non-inductive mechanism is not able to operate. The main objective of this thesis was the study of the non-inductive mechanism under such conditions. For this purpose, we performed experimental measurements of the electric current intensity that acquires a simulated graupel during collisions with ice-crystals and growing by vapor deposition, in absence of supercooled water droplets and, in a second part, under wet growth conditions. The obtained results show that charge transfer, under the conditions studied, is relevant and that the non-inductive electrification mechanism is able to function efficiently under these conditions. Finally, these results could be included in numerical models of thunderstorm electrification to achieve a better representation of them. Fil: Luque, Melina Yasmín. Universidad Nacional de Córdoba. Facultad de Matemática, Astronomía, Física y Computación; Argentina. 2019-09-05T16:08:54Z 2019-09-05T16:08:54Z 2019 bachelorThesis http://hdl.handle.net/11086/12721 spa Atribución–4.0 Internacional https://creativecommons.org/licenses/by/4.0/deed.es
spellingShingle Electricidad atmosférica
Tormentas
Atmospheric electricity
Storms
Electrificación
Nubes de tormenta
Mecanismo no-inductivo
Luque, Melina Yasmín
Electrificación de las nubes de tormenta : el mecanismo no inductivo
title Electrificación de las nubes de tormenta : el mecanismo no inductivo
title_full Electrificación de las nubes de tormenta : el mecanismo no inductivo
title_fullStr Electrificación de las nubes de tormenta : el mecanismo no inductivo
title_full_unstemmed Electrificación de las nubes de tormenta : el mecanismo no inductivo
title_short Electrificación de las nubes de tormenta : el mecanismo no inductivo
title_sort electrificacion de las nubes de tormenta el mecanismo no inductivo
topic Electricidad atmosférica
Tormentas
Atmospheric electricity
Storms
Electrificación
Nubes de tormenta
Mecanismo no-inductivo
url http://hdl.handle.net/11086/12721
work_keys_str_mv AT luquemelinayasmin electrificaciondelasnubesdetormentaelmecanismonoinductivo